Columbia-Spas Aeware Manual de usuario Pagina 40

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 54
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 39
39
in.xm
Warning!
There are different GFCI models used on the market.
See manufacture's instructions that come with the GFCI for
specific information. Note that all illustrations are examples only.
From
electrical box
To spa
Ground
wire
Main electrical box GFCI panel
Verify if GFCI is properly connected.
If it's not, verify GFCI diagram and reconnect it.
Verify in.xm pack wiring (make sure that the neutral and the ground
have not been inverted).
From
electrical box
To spa
Important
connections:
Neutral of
GFCI must be
connected to
neutral bus.
Neutral from
spa must be
connected to
breaker.
If the GFCI is properly connected but still tripping, unplug all
outputs from the spa pack (pumps, heater, ozonator etc).
Reconnect one output at the time until the GFCI trips again.
Replace defective component.
Note: If the neutral of the GFCI is hooked up to the neutral bar,
the in.xm spa control will only trip when the 120v outputs arered
( e.g.: the ozonator)
gfci trips