Columbia-Spas Aeware Manual de usuario Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 54
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
25
in.xm
SP - OT
Internal hardware temp. is too high
Remove spa skirt and let system cool down.
A breaker reset may be required to clear error.
SP - OH & blinking water temp. on the keypad display
water temperature exceeding 112°F is detected
Remove spa cover and let spa cool down.
Add cold water and lower lter cycle.
If the temperature cools down within normal limits the error will
reset itself.
If error persists, measure the temperature with a DIGITAL
thermometer and compare its reading with temp. on the display.
If temp. reading is different, replace in.therm.
If problem persists replace pack.
SP corrective actions